The BinMaster GWR-1000 level sensor measures powders, bulk solids and liquids in vessels up to 78’ tall. It provides highly accurate, continuous level measurement utilizing time domain reflectometry (TDR) to measure the distance, level and volume of material contained in bins, tanks and silos. It performs reliably and is immune to dust, humidity, temperature, pressure and bulk density changes as well as noise that might be present when filling or emptying the vessel.
Using proven technology, the GWR-1000 features advanced two-wire TDR measurement technology with a low dead band (hysteresis) and accuracy of ± 0.2 inches (5 mm). The measurement data is converted to a 4-20 mA output with HART communication and can be viewed via a graphical display on the device or an optional local display using the SAP-300 plug-in display unit. BinMaster offers standard models for process temperatures from -22°F to 195°F (-30°C to 90°C) and high temperature models for temperature extremes from -22°F to 392°F (-30°C to 200°C). An 8 mm cable with a 1.5” NPT is offered for use in liquids and heavier bulk solid materials and a 4 mm cable with a 1” NPT can be used in lighter powders and bulk solids.
Features:
• 2-wire TDR technology
• 4-20 mA with HART communication
• Accuracy of ± 0.2 inches (5 mm)
• Temperature range of -22°F to 195°F
• HT model maximum temperature 392°F
• Graphical display and optional local display
Specifications:
• Dielectric Constant: ≥ 2.1
• Measured Values: Distance, level, volume
• Measuring Range: Up to 78’
• Housing: Aluminum with red epoxy paint
• Enclosure Type: IP65
• Weight: 3.3 lb. (1.5 kg) without cable and probe
• Cable Type: Flexible 0.32” (8 mm) or 0.15” (4 mm) 316 stainless steel mono cable
• Probe Type: Stainless steel Pressure: Up to 232 psi
• Temperature: -22°F to 195°F (-30°C to 90°C) Standard model, -22°F to 392°F (-30°C to 200°C) High Temperature model
• Connection: 1-1/2” NPT with .032” (8 mm) cable, 1” NPT with 0.15” (4 mm) cable
• Power Supply: 18-35 VDC
• Output Signal: 4-20 mA
• Communication Protocol HART
• Approvals: (optional) II 1G Ex ia IIC T6…T3; II 1D iaD; A20/A21 IP65 T100°C
Applications:
• Continuous level measurement in powders, granules, bulk solids, and liquids
• Suitable for vessels of most any shape or diameter, including narrow tanks
• Industries including food, grain, seed, feed, cement, asphalt, minerals, quarries, steel, chemicals, and power generation
• Vessels prone to dust, humidity, temperature, pressure and bulk density changes
Specifications
Description |
N/A 2-Wire guided microwave level transmitter, 18-35 VDC, 4 to 20 mA output with HART, process temperature from –22°F to 195°F (-30°C to 90°C). Aluminum housing with powder coated finish, 1-1/2” stainless steel process connection for use with the single flexible Ø 8 mm 316 stainless steel cable. General purpose IP65. (For local LCD display you must order SAP-300.) |
Material |
N/A Powders, granules, bulk solids and liquids |
Housing Material |
N/A Aluminum with red epoxy pain |
Pressure |
N/A Up to 232 psi |
Power Supply |
N/A 18-35 VDC |
Signal Output |
N/A 4-20 mA |
Enclosure |
N/A IP65 |
Weight |
N/A 3.3 lbs. |
Applications |
N/A Continuous level measurement |
Manufacturer |
N/A BinMaster |