OT-type External Pneumatic Turbine Vibrators combine high frequencies with high centrifugal forces. OT Vibrators are operated oil-free with filtered compressed air. They do not require any maintenance and they are successfully used as flow aids on bins, as drives for chutes or screens, and on vibrating tables. Vibration with the OT-type is generated by a turbine with integrated flyweights rotating on two oversized ball bearings. OT Turbine Vibrators develop high vibration frequencies andmore

Specifications

(B) Inch

3.39

(C) Inch

2.68

(D) Inch

0.47

(E) Inch

1.30

(F) Inch

0.28

(X-Y) Inch

1/8

Weight lbs.

0.56

Frequency at 29psi/2bar

26000 vpm

Frequency at 58psi/4bar

33000 vpm

Frequency at 87psi/6bar

38000 vpm

Centrifugal Force Max at 29psi/2bar

231 lbs

Centrifugal Force Max at 58psi/4bar

377 lbs

Centrifugal Force Max at 87psi/6bar

554 lbs

Air Consumption at 29psi/2bar

1.6 cfm

Air Consumption at 58psi/4bar

2.9 cfm

Air Consumption at 87psi/6bar

3.9 cfm

Manufacturer

OLI