Print Back

The PROCAP Flush Mount Probes offer “no probe intrusion” and are designed for space constrained areas or applications where material flow or bridging may damage a standard probe. It can be mounted on a bin wall, conveyor housing or a chute. The face of the bottom of the FL serves as the capacitance sensor which features Pro-Shield compensation for material build up and an adjustable time delay of up to 30 seconds to ensure accurate readings. The screw-cap enclosure offers easy access to components, which is especially handy in space-constrained installations.
PROCAP Flush Mount Capacitance Probe
Unit of Measure
Items PROCAP Flush Mount Capacitance Probe
PROCAP I FL
PROCAP I FL
PROCAP Flush Mount Capacitance Probe
PROCAP II FL
PROCAP II FL
PROCAP Flush Mount Capacitance Probe
PROCAP XI FL
PROCAP XI FL
PROCAP Flush Mount Capacitance Probe
PROCAP IIX FL
PROCAP IIX FL
PROCAP Remote
PRO Remote 25' FL
PRO Remote 25' FL
Model N/A PROCAP I FL N/A PROCAP II FL N/A PROCAP XI FL N/A PROCAP IIX FL N/A PRO Remote 25' FL
Voltage N/A 24 TO 240 VAC/VDC N/A 115/230 VAC N/A 24 TO 240 VAC/VDC N/A 115/230 VAC N/A 115 VAC
Temperature N/A
Manufacturer N/A BinMaster
Power Requirements N/A N/A N/A 120/240 VAC 50/60 Hz ±15%, 5VA N/A N/A
Output Relay N/A N/A N/A DPDT 10 Amp at 250 VAC N/A N/A
Ambient Temperature Range N/A N/A N/A -40 to 85 ºC-40 to 185 ºF N/A N/A
Sensor Temperature Range N/A N/A N/A 150ºF Standard (65ºC) 450ºF High Temp (232ºC) N/A N/A
Pressure N/A N/A N/A 250 psi, Flush Mount N/A N/A
Sensitivity Setting N/A N/A N/A Adjustable Sensitivity to < 1 PicoFarad N/A N/A
Calibration N/A N/A N/A “Quick Set” Coarse/Fine Single Turn Potentiometers N/A N/A
Fail-Safe Mode N/A N/A N/A Switch Selectable High/Low N/A N/A
Time Delay N/A N/A N/A Adjustable 0.25 to 10 Seconds N/A N/A
Enclosure N/A N/A N/A Cast Aluminum, Bolt-On Cover USDA Approved Finish N/A N/A
Conduit Entry N/A N/A N/A 3/4" NPT N/A N/A
Mounting N/A N/A N/A Flush Mount, Non-Invasive N/A N/A
PRO-Shield N/A N/A N/A Compensates for Material, Build-up on Sensing Probe N/A N/A
Approval Ratings1 N/A N/A N/A NRTL/C, Ratings: NEMA 4X, 5 and 12 N/A N/A
Status Indicator N/A N/A N/A Visual LED indicates sensor status: uncovered, covered and power failure N/A N/A
Prob Options N/A N/A N/A High Temperature Sensor Standard Sensor N/A N/A
  • 1 Note: Also available are Explosion Proof model is for Class I Group C & D and Class II Group E, F, and G