Non-clogging Condensate Drain for Compressed Air Systems


Designed for the toughest applications, this non-clogging, full-port ball valve drain with a solid state timer. removes condensate, (oil and water) from compressed air systems.

How it Removes Condensate from Compressed Air Systems

The BVD Drain is a non-clogging timer-based condensate drain using a full-port ball valve. A heavy-duty gear-motor housed in a NEMA 4X enclosure ensures a long service life. A solid-state timer module initiates a drain cycle by energizing the gear motor to rotate the ball valve 180° from closed to open and back to a closed position. The drain cycle lasts for approximately 8 seconds during which condensate is drained.

Unit of Measure

On Time

N/A Drain Cycle Time 8 secs.

Off Time

N/A Drain Cycle Frequency 1 min. – 50 mins.

Voltage

N/A 115 V/60 HZ/1 PH

Enclosure

N/A NEMA 4X Enclosure

Max. Pressure

N/A Bronze – up to 600 PSI & Stainless Steel – up to 2,000 PSI psi

Thread Size

N/A 1/4" NPT Bronze