Print Back
Unit of Measure

Specifications

Frequency

79 GHz

Antenna Type

integrated horn antenna

Measuring Range

80 ft24 m

Beam Angle

7 to 14 º

Accuracy

less than or equal to 1 mm

Power Requirements

9.6-48 VDC 90-253 VAC

Ambient Temperature

-40 to +80 ºC-40 to +176 ºF

Process Temperature

-196 to +80 ºC-321 to +176 ºF

Operating Voltage

12 to 35 VDC

Process Pressure

Process Pressure

316L:
-1 to 40 bar (-100 to 4000
kPa/-14.5 to 580.2 psig)
PVDF:
-1 to 3 bar (-100 to 300
kPa/-14.5 to 43.51 psig)

Mounting

Mounting

.75” , 1.0” , 1.5” , or 2” NPT
process connection

Enclosure Rating

Enclosure Rating

IP66/IP67, IP66/IP68 (0.2 bar),
IP68 (1 bar), IP69K, NEMA
Type 4X, NEMA Type 6P

Approvals

Approvals

CSA (XP), CSA (DIP), ATEX/
UKEX (XP), ATEX/UKEX
(DIP), IEC (XP), IEC (DIP)

Output

Output

Two-wire 4 - 20 mA/HART®,
Four-wire 4 - 20 mA,
Modbus RTU