Model CP-DMS Dashboard Manager Software
The Crop-Protector™ Dashboard Manager is the software platform that provides a comprehensive overview of all grain storage and monitoring data. The home page of the Dashboard provides an at-a-glance summary of stored grain conditions and control data. Dependent on the configuration of the system, the Dashboard will show grain temperature, grain moisture, weather data, approximate grain level, volume and weight, aeration fan and roof exhaust fan off or on status, and spoilage indication from the CO2 sensor. More detail about each condition can be shown in detail by selecting from a sub-menu that includes options such as trend data, matrix view, inventory trend, alarm settings, fan status, and spoilage indication. The Crop-ProtectorTM Dashboard Manager is an easy-to-use tool that makes the lives of grain managers easy and safe.
Trend data
The trend data chart displays the highest and lowest temperature reading in each silo and the average temperature from all sensors.
Matrix view
The matrix view displays all of the temperatures for each sensor in each sensor cable, as well as a high (H) and low (L).
Model MH Suspension Hooks
Suspension hooks are used when cables are mounted inside the silo and require access to the silo roof from inside the silo for installation. These heavy duty suspension hooks are designed for simple installation and long-lasting durability. Self-locking bolts secure the hook to the sensor to ensure that the bolts never loosen and the cable stays put. The hook can be mounted through an existing opening in the rafter. Several silo manufacturers provide a standard fitting for cable sensor mounting. Alternatively, a hole can be drilled through the rafter, if required.
Features:
• Used for mounting cables from inside the silo
• Simple installation, long-lasting durability
• Self-locking bolt ensures permanent stability
• Install into an existing or drilled hole
Model MP Mounting Plates
Roof mounting plates allow rooftop access to the sensor cable, allowing it to be installed, wired, and serviced from outside the silo. The mounting plate kit comes complete with sealant, self-tapping screws, a template for cutting the hole, and mounting instructions. Nine mounting screws provide a strong attachment to the roof sheets and spread the pulling force of the roof plate to adjacent roof sheets for added strength and stability. Mounting plates may also be mounted near the overlap junction of two roof sheets, displacing the pulling force to both roof sheets. For very large or tall silos, the mounting plate may also be mounted in the middle of the sheet using a one or three-bar support system.
Features:
• Allow installation, wiring and service from outside the silo
• Designed to spread pull force to adjacent roof plates
• Nine mounting bolts provide strength and stability
• Sealant, bolts, template, and instructions included in kit
Model ROU Relay Output Unit
The relay output unit is a control device used for automated control of aeration fans in the Crop-Protector™ system. The units are controlled via the Aeration Control software that uses moisture sensor data to determine when and for how long an aeration fan should run to optimize grain moisture content. Each unit has eight relays with the relay status of open or closed visible on the diodes. Every unit has an individual Modbus address and can be installed where the aeration fans have their power start/stop relays to minimize wiring. One relay will normally control all of the aeration fans for a single bin, allowing for up to eight bins to be controlled via a single relay box. The relay output unit can also be used to control head space ventilation fans, either directly or via a help-relay. Data output (via RS-485 Modbus) directly to a PLC is also available.
Features:
Control device used for automated control of aeration fans and roof ventilation
Unit has 8 relays with each relay’s status visible on the diodes
Crop-Protector™ Aeration Control software indicates need for aeration
Manual or automated fan operation via RS-485 Modbus
Status can be monitored via Aeration Control software on a PC or via the Cloud
Communication: Via RS-485 Modbus to Crop-Protector™ Dashboard
Operation: Automatic or semi-automatic mode as determined in Aeration Control software
DIN Rail Unit:
• 8 relays with normally open (NO) and normally closed (NC) contacts
• Maximum switching power 12 – 24 VDC: 3A and 230 VAC: 10A
• 12 VDC, 600 mA power supply
• Modbus protocol, addressed from 01 to 99 using Crop-Protector™ software
• RS-485; up to 99 relay units in series, up to 3,937 ft. (1200m) on CAT-5e cable
Cabinet Unit:
C• lass IP-65 die-cast aluminum box 6.7 in. x 9.45 in. x 3.15 in. (170mm x 240mm x 80mm)
• 100 – 240 VAC power supply, maximum 10 w with power on indicator