Heavy Duty Combination Starters MCP Type
Across-Line Motor Starters
Features:
• Solid state ESP200 overload relay
• Wide range of enclosure types available
• Flexibility with field modifications
• 100 KA short circuit current rating when protected with class R fuses to 600V
• Industrial type disconnect handle
• Visible blade disconnect
• Easy to install
Features:
• Solid state ESP200 overload relay
• Wide range of enclosure types available
• Flexibility with field modifications
• 100 KA short circuit current rating when protected with class R fuses to 600V
• Industrial type disconnect handle
• Visible blade disconnect
• Easy to install
Item # |
HP at 200 Volts |
HP at 230 Volts |
HP at 460 Volts |
HP at 575 Volts |
Overload Amp Range |
NEMA Size |
Breaker Size |
Coil Voltage |
Frame Size |
Enclosure |
---|---|---|---|---|---|---|---|---|---|---|
18DUE92NL | HP at 200 Volts N/A 7.5 | HP at 230 Volts N/A 7.5 | HP at 460 Volts N/A 10 | HP at 575 Volts N/A | Overload Amp Range N/A 1 | NEMA Size N/A 30 | Breaker Size N/A 10-40 | Coil Voltage N/A 277 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NA | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 110-120/220-240 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NC | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 220-240/440-480 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92ND | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 200-208 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NE | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 550-600 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NF | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 120 Separate Control | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NG | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 220-240 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NH | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 440-480 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NJ | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 24 Separate Control | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18EUE92NL | HP at 200 Volts N/A | HP at 230 Volts N/A | HP at 460 Volts N/A 15 | HP at 575 Volts N/A 15 | Overload Amp Range N/A 1.75 | NEMA Size N/A 40 | Breaker Size N/A 10-40 | Coil Voltage N/A 277 | Frame Size N/A A1 | Enclosure N/A NEMA 12/3/3R |
18FUF92NA | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 110-120/220-240 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NC | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 220-240/440-480 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92ND | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NE | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 550-600 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NF | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 120 Separate Control | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NG | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 220-240 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NH | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 440-480 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18FUF92NL | HP at 200 Volts N/A 10 | HP at 230 Volts N/A 15 | HP at 460 Volts N/A 25 | HP at 575 Volts N/A 25 | Overload Amp Range N/A 2 | NEMA Size N/A 50 | Breaker Size N/A 13-52 | Coil Voltage N/A 277 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NA | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 110-120/220-240 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NC | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 220-240/440-480 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92ND | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NE | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 550-600 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NF | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 120 Separate Control | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NG | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 220-240 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18GUG92NH | HP at 200 Volts N/A 15 | HP at 230 Volts N/A 20 | HP at 460 Volts N/A 30 | HP at 575 Volts N/A 30 | Overload Amp Range N/A 2.5 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 440-480 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |