Heavy Duty Combination Starters MCP Type
Across-Line Motor Starters
Features:
• Solid state ESP200 overload relay
• Wide range of enclosure types available
• Flexibility with field modifications
• 100 KA short circuit current rating when protected with class R fuses to 600V
• Industrial type disconnect handle
• Visible blade disconnect
• Easy to install
Features:
• Solid state ESP200 overload relay
• Wide range of enclosure types available
• Flexibility with field modifications
• 100 KA short circuit current rating when protected with class R fuses to 600V
• Industrial type disconnect handle
• Visible blade disconnect
• Easy to install
Item # |
HP at 200 Volts |
HP at 230 Volts |
HP at 460 Volts |
HP at 575 Volts |
Overload Amp Range |
NEMA Size |
Breaker Size |
Coil Voltage |
Frame Size |
Enclosure |
---|---|---|---|---|---|---|---|---|---|---|
18HUG92WD | HP at 200 Volts N/A 25 | HP at 230 Volts N/A 30 | HP at 460 Volts N/A 50 | HP at 575 Volts N/A 50 | Overload Amp Range N/A 3 | NEMA Size N/A 100 | Breaker Size N/A 25-100 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 4/4X Stainless |
18IUH92BD | HP at 200 Volts N/A 30 | HP at 230 Volts N/A 40 | HP at 460 Volts N/A 75 | HP at 575 Volts N/A 75 | Overload Amp Range N/A 3.5 | NEMA Size N/A 125 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 1 |
18IUH92FD | HP at 200 Volts N/A 30 | HP at 230 Volts N/A 40 | HP at 460 Volts N/A 75 | HP at 575 Volts N/A 75 | Overload Amp Range N/A 3.5 | NEMA Size N/A 125 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 4X Fiberglass |
18IUH92HD | HP at 200 Volts N/A 30 | HP at 230 Volts N/A 40 | HP at 460 Volts N/A 75 | HP at 575 Volts N/A 75 | Overload Amp Range N/A 3.5 | NEMA Size N/A 125 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 7&9/3&4 |
18IUH92ND | HP at 200 Volts N/A 30 | HP at 230 Volts N/A 40 | HP at 460 Volts N/A 75 | HP at 575 Volts N/A 75 | Overload Amp Range N/A 3.5 | NEMA Size N/A 125 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18IUH92WD | HP at 200 Volts N/A 30 | HP at 230 Volts N/A 40 | HP at 460 Volts N/A 75 | HP at 575 Volts N/A 75 | Overload Amp Range N/A 3.5 | NEMA Size N/A 125 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 4/4X Stainless |
18JUH92BD | HP at 200 Volts N/A 40 | HP at 230 Volts N/A 50 | HP at 460 Volts N/A 100 | HP at 575 Volts N/A 100 | Overload Amp Range N/A 4 | NEMA Size N/A 150 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 1 |
18JUH92FD | HP at 200 Volts N/A 40 | HP at 230 Volts N/A 50 | HP at 460 Volts N/A 100 | HP at 575 Volts N/A 100 | Overload Amp Range N/A 4 | NEMA Size N/A 150 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 4X Fiberglass |
18JUH92HD | HP at 200 Volts N/A 40 | HP at 230 Volts N/A 50 | HP at 460 Volts N/A 100 | HP at 575 Volts N/A 100 | Overload Amp Range N/A 4 | NEMA Size N/A 150 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 7&9/3&4 |
18JUH92ND | HP at 200 Volts N/A 40 | HP at 230 Volts N/A 50 | HP at 460 Volts N/A 100 | HP at 575 Volts N/A 100 | Overload Amp Range N/A 4 | NEMA Size N/A 150 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 12/3/3R |
18JUH92WD | HP at 200 Volts N/A 40 | HP at 230 Volts N/A 50 | HP at 460 Volts N/A 100 | HP at 575 Volts N/A 100 | Overload Amp Range N/A 4 | NEMA Size N/A 150 | Breaker Size N/A 50-200 | Coil Voltage N/A 200-208 | Frame Size N/A B | Enclosure N/A NEMA 4/4X Stainless |
18LPT92BD | HP at 200 Volts N/A 50 | HP at 230 Volts N/A 75 | HP at 460 Volts N/A 150 | HP at 575 Volts N/A 200 | Overload Amp Range N/A 5 | NEMA Size N/A 250 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 1 |
18LPT92HD | HP at 200 Volts N/A 50 | HP at 230 Volts N/A 75 | HP at 460 Volts N/A 150 | HP at 575 Volts N/A 200 | Overload Amp Range N/A 5 | NEMA Size N/A 250 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 7&9/3&4 |
18LPT92ND | HP at 200 Volts N/A 50 | HP at 230 Volts N/A 75 | HP at 460 Volts N/A 150 | HP at 575 Volts N/A 200 | Overload Amp Range N/A 5 | NEMA Size N/A 250 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 12/3/3R |
18LPT92WD | HP at 200 Volts N/A 50 | HP at 230 Volts N/A 75 | HP at 460 Volts N/A 150 | HP at 575 Volts N/A 200 | Overload Amp Range N/A 5 | NEMA Size N/A 250 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 4/4X Stainless |
18LPU92BD | HP at 200 Volts N/A 75 | HP at 230 Volts N/A 100 | HP at 460 Volts N/A 200 | HP at 575 Volts N/A | Overload Amp Range N/A 5 | NEMA Size N/A 400 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 1 |
18LPU92HD | HP at 200 Volts N/A 75 | HP at 230 Volts N/A 100 | HP at 460 Volts N/A 200 | HP at 575 Volts N/A | Overload Amp Range N/A 5 | NEMA Size N/A 400 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 7&9/3&4 |
18LPU92ND | HP at 200 Volts N/A 75 | HP at 230 Volts N/A 100 | HP at 460 Volts N/A 200 | HP at 575 Volts N/A | Overload Amp Range N/A 5 | NEMA Size N/A 400 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 12/3/3R |
18LPU92WD | HP at 200 Volts N/A 75 | HP at 230 Volts N/A 100 | HP at 460 Volts N/A 200 | HP at 575 Volts N/A | Overload Amp Range N/A 5 | NEMA Size N/A 400 | Breaker Size N/A 55-250 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 4/4X Stainless |
18MPW92BD | HP at 200 Volts N/A 100 | HP at 230 Volts N/A 125 | HP at 460 Volts N/A 250 | HP at 575 Volts N/A 300 | Overload Amp Range N/A 6 | NEMA Size N/A 400 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 1 |
18MPW92ND | HP at 200 Volts N/A 100 | HP at 230 Volts N/A 125 | HP at 460 Volts N/A 250 | HP at 575 Volts N/A 300 | Overload Amp Range N/A 6 | NEMA Size N/A 400 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 12/3/3R |
18MPW92WD | HP at 200 Volts N/A 100 | HP at 230 Volts N/A 125 | HP at 460 Volts N/A 250 | HP at 575 Volts N/A 300 | Overload Amp Range N/A 6 | NEMA Size N/A 400 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 4/4X Stainless |
18MPX92BD | HP at 200 Volts N/A 150 | HP at 230 Volts N/A 200 | HP at 460 Volts N/A 400 | HP at 575 Volts N/A 400 | Overload Amp Range N/A 6 | NEMA Size N/A 600 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 1 |
18MPX92ND | HP at 200 Volts N/A 150 | HP at 230 Volts N/A 200 | HP at 460 Volts N/A 400 | HP at 575 Volts N/A 400 | Overload Amp Range N/A 6 | NEMA Size N/A 600 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 12/3/3R |
18MPX92WD | HP at 200 Volts N/A 150 | HP at 230 Volts N/A 200 | HP at 460 Volts N/A 400 | HP at 575 Volts N/A 400 | Overload Amp Range N/A 6 | NEMA Size N/A 600 | Breaker Size N/A 160-630 | Coil Voltage N/A 200-208 | Frame Size N/A | Enclosure N/A NEMA 4/4X Stainless |