WorldWide Electric’s line of Explosion Proof motors are designed and built to meet both Class I and Class II requirements. These motors are fully tested in order to obtain an explosion proof rating.
*Currently being redesigned to include inverter duty to withstand the higher voltage produced by VFDs.
Features:
• 2-300 HP
• 1800 RPM
• 208-230/460 volt (2-100 HP)
• 460 volt (125-300 HP)
• TEXP enclosure
• 1.15 service factor
• Class F insulation
• C-face - rigid base
• Premium efficiency (2-200 HP)
• High efficiency (250-300 HP)
• Inverter duty, 5:1 CT / 10:1 VT (1-200 HP only)
• Three normally closed winding thermostats provided (one per phase)
• UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
• 145TC-215TC: Class 1, Div. 1, Groups C & D; T3C; inverter duty (1-200 HP); 55ºC amb. temp.
• 254TC-449TC: Class 1, Div. 1, Groups C & D; T2C; inverter duty (1-200 HP); 55ºC amb. temp.
• Three-Phase
Item # |
HP |
RPM |
Voltage |
Frame |
Enclosure |
FL Amps (A) |
FL Eff. (%) |
Approx. Weight (lbs.) |
Certifications |
---|---|---|---|---|---|---|---|---|---|
IXPEWWE2-18-145TC | N/A 2 | N/A 1800 | N/A 208-230/460 | N/A 145TC | N/A TEXP | N/A 2.8 | N/A 86.5 | N/A 73 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
IXPEWWE3-18-182TC | N/A 3 | N/A 1800 | N/A 208-230/460 | N/A 145TC | N/A TEXP | N/A 3.8 | N/A 89.5 | N/A 121 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
IXPEWWE5-18-184TC | N/A 5 | N/A 1800 | N/A 208-230/460 | N/A 184T | N/A TEXP | N/A 6.2 | N/A 89.5 | N/A 131 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
IXPEWWE7.5-18-213TC | N/A 7.5 | N/A 1800 | N/A 208-230/460 | N/A 213TC | N/A TEXP | N/A 9.2 | N/A 91.7 | N/A 237 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
IXPEWWE10-18-215TC | N/A 10 | N/A 1800 | N/A 208-230/460 | N/A 215TC | N/A TEXP | N/A 12.4 | N/A 91.7 | N/A 243 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
IXPEWWE15-18-254TC | N/A 15 | N/A 1800 | N/A 208-230/460 | N/A 215TC | N/A TEXP | N/A 16.9 | N/A 92.4 | N/A 393 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE20-18-256TC | N/A 20 | N/A 1800 | N/A 208-230/460 | N/A 256TC | N/A TEXP | N/A 23 | N/A 93 | N/A 435 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE25-18-284TC | N/A 25 | N/A 1800 | N/A 208-230/460 | N/A 284TC | N/A TEXP | N/A 27.9 | N/A 93.6 | N/A 516 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE30-18-286TC | N/A 30 | N/A 1800 | N/A 208-230/460 | N/A 286TC | N/A TEXP | N/A 33 | N/A 93.6 | N/A 523 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE40-18-324TC | N/A 40 | N/A 1800 | N/A 208-230/460 | N/A 324TC | N/A TEXP | N/A 45.5 | N/A 94.1 | N/A 670 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE50-18-326TC | N/A 50 | N/A 1800 | N/A 208-230/460 | N/A 326TC | N/A TEXP | N/A 57 | N/A 94.5 | N/A 715 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE60-18-364TC | N/A 60 | N/A 1800 | N/A 208-230/460 | N/A 364TC | N/A TEXP | N/A 68.5 | N/A 95 | N/A 920 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE75-18-365TC | N/A 75 | N/A 1800 | N/A 208-230/460 | N/A 365TC | N/A TEXP | N/A 83.5 | N/A 95.4 | N/A 985 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE100-18-405TC | N/A 100 | N/A 1800 | N/A 208-230/460 | N/A 405TC | N/A TEXP | N/A 113 | N/A 95.4 | N/A 1350 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE125-18-444/5TC | N/A 125 | N/A 1800 | N/A 460 | N/A 444/5TC | N/A TEXP | N/A 134 | N/A 95.4 | N/A 1555 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE150-18-444/5TC | N/A 150 | N/A 1800 | N/A 460 | N/A 444/5TC | N/A TEXP | N/A 163 | N/A 95.8 | N/A 1740 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XPEWWE200-18-445/7/9TC | N/A 200 | N/A 1800 | N/A 460 | N/A 444/5TC | N/A TEXP | N/A 223 | N/A 96.2 | N/A 1990 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XWWE250-18-447/9TC | N/A 250 | N/A 1800 | N/A 460 | N/A 447/9TC | N/A TEXP | N/A 275 | N/A 95.2 | N/A 2560 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |
XWWE300-18-447/9TC | N/A 300 | N/A 1800 | N/A 460 | N/A 447/9TC | N/A TEXP | N/A 325 | N/A 95.4 | N/A 2745 | N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard |