WorldWide Electric’s line of Explosion Proof motors are designed and built to meet both Class I and Class II requirements. These motors are fully tested in order to obtain an explosion proof rating.

*Currently being redesigned to include inverter duty to withstand the higher voltage produced by VFDs.

Features:
• 2-300 HP
• 1800 RPM
• 208-230/460 volt (2-100 HP)
• 460 volt (125-300 HP)
• TEXP enclosure
• 1.15 service factor
• Class F insulation
• C-face - rigid base
• Premium efficiency (2-200 HP)
• High efficiency (250-300 HP)
• Inverter duty, 5:1 CT / 10:1 VT (1-200 HP only)
• Three normally closed winding thermostats provided (one per phase)
• UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
• 145TC-215TC: Class 1, Div. 1, Groups C & D; T3C; inverter duty (1-200 HP); 55ºC amb. temp.
• 254TC-449TC: Class 1, Div. 1, Groups C & D; T2C; inverter duty (1-200 HP); 55ºC amb. temp.
• Three-Phase

1 - 19 of 19 | Results Per Page | View |
1 

Item #

HP

RPM

Voltage

Frame

Enclosure

FL Amps (A)

FL Eff. (%)

Approx. Weight (lbs.)

Certifications

N/A 2 N/A 1800 N/A 208-230/460 N/A 145TC N/A TEXP N/A 2.8 N/A 86.5 N/A 73 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 3 N/A 1800 N/A 208-230/460 N/A 145TC N/A TEXP N/A 3.8 N/A 89.5 N/A 121 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 5 N/A 1800 N/A 208-230/460 N/A 184T N/A TEXP N/A 6.2 N/A 89.5 N/A 131 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 7.5 N/A 1800 N/A 208-230/460 N/A 213TC N/A TEXP N/A 9.2 N/A 91.7 N/A 237 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 10 N/A 1800 N/A 208-230/460 N/A 215TC N/A TEXP N/A 12.4 N/A 91.7 N/A 243 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 15 N/A 1800 N/A 208-230/460 N/A 215TC N/A TEXP N/A 16.9 N/A 92.4 N/A 393 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 20 N/A 1800 N/A 208-230/460 N/A 256TC N/A TEXP N/A 23 N/A 93 N/A 435 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 25 N/A 1800 N/A 208-230/460 N/A 284TC N/A TEXP N/A 27.9 N/A 93.6 N/A 516 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 30 N/A 1800 N/A 208-230/460 N/A 286TC N/A TEXP N/A 33 N/A 93.6 N/A 523 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 40 N/A 1800 N/A 208-230/460 N/A 324TC N/A TEXP N/A 45.5 N/A 94.1 N/A 670 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 50 N/A 1800 N/A 208-230/460 N/A 326TC N/A TEXP N/A 57 N/A 94.5 N/A 715 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 60 N/A 1800 N/A 208-230/460 N/A 364TC N/A TEXP N/A 68.5 N/A 95 N/A 920 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 75 N/A 1800 N/A 208-230/460 N/A 365TC N/A TEXP N/A 83.5 N/A 95.4 N/A 985 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 100 N/A 1800 N/A 208-230/460 N/A 405TC N/A TEXP N/A 113 N/A 95.4 N/A 1350 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 125 N/A 1800 N/A 460 N/A 444/5TC N/A TEXP N/A 134 N/A 95.4 N/A 1555 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 150 N/A 1800 N/A 460 N/A 444/5TC N/A TEXP N/A 163 N/A 95.8 N/A 1740 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 200 N/A 1800 N/A 460 N/A 444/5TC N/A TEXP N/A 223 N/A 96.2 N/A 1990 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 250 N/A 1800 N/A 460 N/A 447/9TC N/A TEXP N/A 275 N/A 95.2 N/A 2560 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
N/A 300 N/A 1800 N/A 460 N/A 447/9TC N/A TEXP N/A 325 N/A 95.4 N/A 2745 N/A UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard