Features:
• Square-wave pulse frequency output,NPN open-collector
• Zero speed operation with no signal loss
• 5-24 VDC powered
• Non-contact, large gap distance sensing
• Bidirectional (quadrature) option
• Works with Electro-Sensors magnetic pulser discs / wraps
• Optional Mounting Bracket Assembly and Mounting Magnet
• Class I, Div I (D) Class II, Div I (E, F, G) Class III
• XLB-3 enclosure
907 XP sensors are used in applications requiring hazardous location ratings, or in applications where the sensor may be subject to abuse. It has a 1-inch NPT conduit opening for wiring, terminal strip for wiring, and is provided with a mounting bracket and 10 ft of cable. The quadrature (bidirectional) option has two sensors and is designed for applications requiring both speed and direction information. Specify vertical alignment when the magnets will pass vertically in front of the sensor face, and horizontal alignment when the magnets will pass horizontally in front of the sensor face.
These speed sensors use magnet-sensing Hall Effect IC's to produce a digital pulse signal to interface with speed switches, tachometers, counters, signal conditioners, or PLC's. Hall Effect sensors provide true zero speed operation with square-wave output and immunity to electrical noise.
A pulser disc or split collar pulser wrap with embedded magnets is mounted on the monitored shaft. As the shaft rotates, the magnets pass in front of the sensor causing the sensor to switch high and low, thus producing a digital pulse output. The sensors provide a digital square wave signal with a 50/50 duty cycle when used with pulse generators that have evenly spaced magnets of alternating polarity, such as Electro-Sensors Model 255 Pulser Disc. The recommended gap distance between the sensor and pulse generator is 1/4 inch +/- 1/8 inch. The gap flexibility makes the sensors tolerant of vibration, shaft run-out, misalignment, and industrial environments.
Item # |
Power Supply |
Output Type |
Operating Temperature |
Cable |
Certifications |
---|---|---|---|---|---|
775-000600 775-000600/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A 10 ft PVC | Certifications N/A ISO 9001 |
775-000601 775-000601/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A 10 ft PVC | Certifications N/A ISO 9001 |
775-000602 775-000602/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A 10 ft Teflon | Certifications N/A ISO 9001 |
775-0006100 775-0006100/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A Quadrature, 10 ft PVC | Certifications N/A ISO 9001 |
775-0006101 775-0006101/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A Quadrature, 10 ft PVC | Certifications N/A ISO 9001 |
775-0006102 775-0006102/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A Quadrature, 10 ft Teflon | Certifications N/A ISO 9001 |
775-0006105 775-0006105/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A Quadrature, 50 ft PVC | Certifications N/A ISO 9001 |
775-0006110 775-0006110/Asset/907 XP Hall Effect Image.png | Power Supply N/A 5-24 VDC at 10 mA | Output Type N/A NPN Open Collector | Operating Temperature N/A -40°F to +140°F | Cable N/A Quadrature, 100 ft PVC | Certifications N/A ISO 9001 |