The IQ plus 710 is an economical solution to automated process control. Whether your application requires adding multiple ingredients to a batch, turning on a motor, or starting a conveyor, the IQ plus 710 can execute a variety of complex tasks. The IQ plus 710 is available in both flat and sloped-face enclosure styles.
Standard Features:
•Stainless steel NEMA 4X/IP66 washdown enclosure
•Large 0.75” (19 mm) Vacuum Fluorescent Display (VFD) with 16 characters for operator prompting
•Selectable analog to digital measurement rate
•5-point linearization calibration
•4 macros, 30 steps each, ability to interconnect macros with setpoints (macro can start batch setpoints)
•8 digital inputs plus 8 digital outputs
•60 16-character programmable fields for display prompts
•Power for eight 350 ohm load cells or sixteen 700 ohm load cells
•Expanded 29-key alphanumeric keyboard
•Full alphanumeric keyboard for entering truck ID, numbering, prompts, and more
•300-ID truck in/out programs (six modes), 7 characters
•Batching and continuous mode setpoint functions
•Programmable consecutive numbering
•Two communication ports: (1) EDP port, full duplex RS-232 or RS-485, (1) printer port, simplex RS-232 or 20 mA
•Operate, configure, and calibrate via 2 interfaces: front panel (keyboard & display) or EDP serial command port (RS-232, RS-485)
•Six 300-character programmable output formats, independent transmission to EPD or printer port
•300-character alphanumeric “title block” for custom printouts
•Completely menu driven
•Angled/sloped keypad for user comfort
•Time and date
•Accumulator
Item # |
Power |
Frequency (Hz) |
Power Consumption |
Excitation |
Analog Signal Input Range |
Measurement Rate |
Analog Signal Sensitivty |
Serial Ports |
Circuit Protection |
System Linearity |
Digital I/O |
Keyboard |
Operating Temp. Range |
Rating/Material |
Warranty |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
44545 44545/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |
44544 44544/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |
44527 44527/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |
44528 44528/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |
52052 52052/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |
52051 52051/Asset/IQ Plus 710 Discontinued.png | Power N/A 115 or 230VAC | Frequency (Hz) N/A 50 or 60 Hz | Power Consumption N/A 100 mA at 115VAC / 50 mA at 230VAC | Excitation N/A 10VDC, 8 x 350 load cells or 16 x 700 load cells | Analog Signal Input Range N/A -0.5-4.5mN/V (max) | Measurement Rate N/A 30,15,7-1/2,3-3/4 per second | Analog Signal Sensitivty N/A 0.3µV with digital filters at 4 | Serial Ports N/A Two ports | Circuit Protection N/A RFI, EMI, ESD protection | System Linearity N/A Within 0.01% of FS | Digital I/O N/A 8 digital inputs, 8 digital open collector outputs | Keyboard N/A Full 29-key alphanumeric flat membrane panel | Operating Temp. Range N/A 14 to 122 ºF-10 to 50 ºC | Rating/Material N/A NEMA 4M/IP66, stainless steel | Warranty N/A Two-year limited warranty |