Single Phase - 230 Volt Definite Purpose Motor Starters
    Across-Line Motor Starters
        
    
    
            
                
            
        
        
    
                            Item # | 
                        
                            Coil Voltage | 
                        
                            HP | 
                        
                            Overload Current Setting | 
                        
                            FL Amps (A) | 
                        
                            Auxiliary Contacts | 
                        
                            Dimensions | 
                        
                            Box Size | 
                                                        
|---|---|---|---|---|---|---|---|
| WWS0.5-2301P WWS0.5-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 1/2 | Overload Current Setting N/A 4-6 | FL Amps (A) N/A 4.9 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS0.75-2301P WWS0.75-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 3/4 | Overload Current Setting N/A 5-8 | FL Amps (A) N/A 6.9 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS1-2301P WWS1-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 1 | Overload Current Setting N/A 6-9 | FL Amps (A) N/A 8 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS1.5-2301P WWS1.5-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 1.5 | Overload Current Setting N/A 9-13 | FL Amps (A) N/A 10 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS2-2301P WWS2-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 2 | Overload Current Setting N/A 9-13 | FL Amps (A) N/A 12 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS3-2301P WWS3-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 3 | Overload Current Setting N/A 12-18 | FL Amps (A) N/A 17 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS5-2301P WWS5-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 5 | Overload Current Setting N/A 22-32 | FL Amps (A) N/A 28 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS7.5-2301P WWS7.5-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 7.5 | Overload Current Setting N/A 34-50 | FL Amps (A) N/A 40 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A B | 
| WWS10-2301P WWS10-2301P/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 230 | HP N/A 10 | Overload Current Setting N/A 45-65 | FL Amps (A) N/A 50 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 13.25 x 7.38 x 6.13 | Box Size N/A B | 
| WWS0.5-2301P-120C WWS0.5-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 1/2 | Overload Current Setting N/A 4-6 | FL Amps (A) N/A 4.9 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS0.75-2301P-120C WWS0.75-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 3/4 | Overload Current Setting N/A 5-8 | FL Amps (A) N/A 6.9 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS1-2301P-120C WWS1-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 1 | Overload Current Setting N/A 6-9 | FL Amps (A) N/A 8 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS1.5-2301P-120C WWS1.5-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 1.5 | Overload Current Setting N/A 9-13 | FL Amps (A) N/A 10 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS2-2301P-120C WWS2-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 2 | Overload Current Setting N/A 9-13 | FL Amps (A) N/A 12 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS3-2301P-120C WWS3-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 3 | Overload Current Setting N/A 12-18 | FL Amps (A) N/A 17 | Auxiliary Contacts N/A 1NO+1NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS5-2301P-120C WWS5-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 5 | Overload Current Setting N/A 22-32 | FL Amps (A) N/A 28 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A A | 
| WWS7.5-2301P-120C WWS7.5-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 7.5 | Overload Current Setting N/A 34-50 | FL Amps (A) N/A 40 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 10 x 6 x 4.63 | Box Size N/A B | 
| WWS10-2301P-120C WWS10-2301P-120C/Asset/WWE Single Phase - 230 Volt Definite Purpose Motor Starters.jpg | Coil Voltage N/A 115 | HP N/A 10 | Overload Current Setting N/A 45-65 | FL Amps (A) N/A 50 | Auxiliary Contacts N/A 2NO+2NC | Dimensions N/A 13.25 x 7.38 x 6.13 | Box Size N/A B | 
            