The Valvair II valve is a robust, versatile valve that is well suited for general to harsh industrial applications, such as concrete aggregate plants and steel mills. It offers flow factors up to 12 Cv. The valve can be installed as a single inline or subbase valve for point-of-use applications, or mounted on segmented manifolds for centralized applications. A variety of operators are available from air piloted to solenoid air piloted, with direct conduit or junction box electrical connection. The valves are field converted from standard internal to external pilot operated service, and are suitable for non-lube operation. Dynamic urethane o-rings with an off-center parting line, coupled with Nituf coated and hardened aluminum spools, create a valve with improved lubrication retention and low friction operation. Sandwich pressure regulators can also be added to the valve stack to control air pressure at each valve application.
• Function(s): 5/2 , 5/3
• Operations: Solenoid Air & Remote Pilot Operated
• Manual Operator: Non-Locking and Locking Manual Overrides
• Mounting Type: Inline, Manifold, Single Subbase
• Port Sizes (inch): 3/8, 1/2, 3/4, 1, 1-1/4
• Port Type: NPT
• Flow Min (Cv): 4.5
• Flow Max (Cv): 12
• Voltage Range: 12VDC to 240AC
• Solenoid Connection Type(s): Conduit, JIC
• Certifications/Approvals: General Purpose CSA, Hazardous Duty : UL & CSA, NEMA 4 options
• Pressure Range (psig): 0 to 250
• Pressure Range (bar): 0 to 17
• Solenoid Minimum Operating Pressure (psig): 35
• Temperature Range (c): 0 to 93
• Temperature Range (F): 0 to 200
• Media: Air
• Lubrication: Non Lube
• Body Material: Aluminum Alloy
• Seal Material: Nitrile
• Coil Rating: Class B
• Unique Feature: Sandwich Regulators
Item # |
Type |
Operator |
Size |
Duty Cycle |
Voltage |
---|---|---|---|---|---|
L65 43110245 L65 43110245/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 12 VDC |
L65 43110249 L65 43110249/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 24 VDC |
L65 43110253 L65 43110253/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 120 VAC, 60 Hz |
L65 43110257 L65 43110257/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 110 VAC, 50 Hz |
L65 43110445 L65 43110445/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 12 VDC |
L65 43110449 L65 43110449/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 24 VDC |
L65 43110453 L65 43110453/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 120 VAC, 60 Hz |
L65 43110457 L65 43110457/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 110 VAC, 50 Hz |
L65 43310245 L65 43310245/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 12 VDC |
L65 43310249 L65 43310249/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 24 VDC |
L65 43310253 L65 43310253/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 120 VAC, 60 Hz |
L65 43310257 L65 43310257/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 110 VAC, 50 Hz |
L65 43310445 L65 43310445/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 12 VDC |
L65 43310449 L65 43310449/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 24 VDC |
L65 43310453 L65 43310453/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 120 VAC, 60 Hz |
L65 43310457 L65 43310457/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 110 VAC, 50 Hz |
L65 43810245 L65 43810245/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 12 VDC |
L65 43810249 L65 43810249/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 24 VDC |
L65 43810253 L65 43810253/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 120 VAC, 60 Hz |
L65 43810257 L65 43810257/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Standard Service Solenoid or Remote | Voltage N/A 110 VAC, 50 Hz |
L65 43810445 L65 43810445/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 12 VDC |
L65 43810449 L65 43810449/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 24 VDC |
L65 43810453 L65 43810453/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 120 VAC, 60 Hz |
L65 43810457 L65 43810457/Asset/Parker Valvair II Double Solenoid Valve.jpg | Type N/A Double | Operator N/A Remote | Size N/A 3/8" Basic | Duty Cycle N/A Continuous Service Solenoid | Voltage N/A 110 VAC, 50 Hz |