Closed Coupled Pump Motors
Electric Motors
WorldWide Electric’s Closed Coupled Pump motors feature 1-50 HP, 3600 and 1800 rpm, a TEFC enclosure, and are rated with a 1.15 service factor. Available in both JM and JP configurations.
Features:
• 1-50 HP
• 3600 and 1800 RPM
• 208-230/460 volt
• TEFC enclosure
• 1.15 service factor
• Class F insulation
• C-face - rigid base
• High efficiency
• Suitable for 50 hz operation with 1.0 service factor
• Three-Phase
1 2
Item # |
HP |
RPM |
Voltage |
Frame |
Enclosure |
FL Amps (A) |
FL Eff. (%) |
Approx. Weight (lbs.) |
---|---|---|---|---|---|---|---|---|
WWE1-18-143JM WWE1-18-143JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 1 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 143JM | Enclosure N/A TEFC | FL Amps (A) N/A 1.5 | FL Eff. (%) N/A 82.5 | Approx. Weight (lbs.) N/A 55 |
WWE1-18-143JP WWE1-18-143JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 1 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 143JP | Enclosure N/A TEFC | FL Amps (A) N/A 1.5 | FL Eff. (%) N/A 82.5 | Approx. Weight (lbs.) N/A 50 |
WWE1.5-36-143JM WWE1.5-36-143JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 1.5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 143JM | Enclosure N/A TEFC | FL Amps (A) N/A 1.9 | FL Eff. (%) N/A 82.5 | Approx. Weight (lbs.) N/A 50 |
WWE1.5-18-145JM WWE1.5-18-145JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 1.5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 145JM | Enclosure N/A TEFC | FL Amps (A) N/A 2.1 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 55 |
WWE1.5-18-145JP WWE1.5-18-145JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 1.5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 145JP | Enclosure N/A TEFC | FL Amps (A) N/A 2.1 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 55 |
WWE2-36-145JM WWE2-36-145JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 2 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 145JM | Enclosure N/A TEFC | FL Amps (A) N/A 2.5 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 50 |
WWE2-36-145JP WWE2-36-145JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 2 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 145JP | Enclosure N/A TEFC | FL Amps (A) N/A 2.5 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 50 |
WWE2-18-145JM WWE2-18-145JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 2 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 145JM | Enclosure N/A TEFC | FL Amps (A) N/A 2.7 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 60 |
WWE2-18-145JP WWE2-18-145JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 2 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 145JP | Enclosure N/A TEFC | FL Amps (A) N/A 2.7 | FL Eff. (%) N/A 84.0 | Approx. Weight (lbs.) N/A 60 |
WWE3-36-145JM WWE3-36-145JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 145JM | Enclosure N/A TEFC | FL Amps (A) N/A 3.6 | FL Eff. (%) N/A 85.5 | Approx. Weight (lbs.) N/A 60 |
WWE3-36-145JP WWE3-36-145JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 145JP | Enclosure N/A TEFC | FL Amps (A) N/A 3.6 | FL Eff. (%) N/A 85.5 | Approx. Weight (lbs.) N/A 60 |
WWE3-36-182JM WWE3-36-182JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 182JM | Enclosure N/A TEFC | FL Amps (A) N/A 3.6 | FL Eff. (%) N/A 85.5 | Approx. Weight (lbs.) N/A 92 |
WWE3-36-182JP WWE3-36-182JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 182JP | Enclosure N/A TEFC | FL Amps (A) N/A 3.6 | FL Eff. (%) N/A 85.5 | Approx. Weight (lbs.) N/A 92 |
WWE3-18-182JM WWE3-18-182JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 182JM | Enclosure N/A TEFC | FL Amps (A) N/A 3.9 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 90 |
WWE3-18-182JP WWE3-18-182JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 3 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 182JP | Enclosure N/A TEFC | FL Amps (A) N/A 3.9 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 90 |
WWE5-36-184JM WWE5-36-184JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 184JM | Enclosure N/A TEFC | FL Amps (A) N/A 5.7 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 101 |
WWE5-36-184JP WWE5-36-184JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 184JP | Enclosure N/A TEFC | FL Amps (A) N/A 5.7 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 101 |
WWE5-18-184JM WWE5-18-184JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 184JM | Enclosure N/A TEFC | FL Amps (A) N/A 5.9 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 110 |
WWE5-18-184JP WWE5-18-184JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 184JP | Enclosure N/A TEFC | FL Amps (A) N/A 5.9 | FL Eff. (%) N/A 87.5 | Approx. Weight (lbs.) N/A 110 |
WWE7.5-36-184JM WWE7.5-36-184JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 184JM | Enclosure N/A TEFC | FL Amps (A) N/A 8.4 | FL Eff. (%) N/A 88.5 | Approx. Weight (lbs.) N/A 112 |
WWE7.5-36-184JP WWE7.5-36-184JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 184JP | Enclosure N/A TEFC | FL Amps (A) N/A 8.4 | FL Eff. (%) N/A 88.5 | Approx. Weight (lbs.) N/A 112 |
WWE7.5-36-213JM WWE7.5-36-213JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 213JM | Enclosure N/A TEFC | FL Amps (A) N/A 8.4 | FL Eff. (%) N/A 88.5 | Approx. Weight (lbs.) N/A 148 |
WWE7.5-36-213JP WWE7.5-36-213JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 3600 | Voltage N/A 208-230/460 | Frame N/A 213JP | Enclosure N/A TEFC | FL Amps (A) N/A 8.4 | FL Eff. (%) N/A 88.5 | Approx. Weight (lbs.) N/A 148 |
WWE7.5-18-213JM WWE7.5-18-213JM/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 213JM | Enclosure N/A TEFC | FL Amps (A) N/A 9.3 | FL Eff. (%) N/A 89.5 | Approx. Weight (lbs.) N/A 150 |
WWE7.5-18-213JP WWE7.5-18-213JP/Asset/WWE Closed Coupled Pump Motors.jpg | HP N/A 7.5 | RPM N/A 1800 | Voltage N/A 208-230/460 | Frame N/A 213JP | Enclosure N/A TEFC | FL Amps (A) N/A 9.3 | FL Eff. (%) N/A 89.5 | Approx. Weight (lbs.) N/A 150 |