The single-piece flow detector is a flow/no flow detector that, unlike the two-piece flow detector, houses both the remote sensor and control console in a single NEMA 4X enclosure. An important benefit of the Flow Detect 2000 is that it helps prevent cross contamination by ensuring flow has stopped before a new material is introduced into the flow stream. It is ideal for detecting flow conditions of solids and powders in gravity chutes, feeders, pipelines, conveyor belts, or bucket elevators. It is suitable for most industries, including the feed, grain, milling, food, cement, mining, power and plastics industries.


The Flow Detect 2000 uses microwave Doppler technology for highly sensitive motion detection, which is able to pass through non-metallic materials. This provides the device with the ability to 'see through' a plastic pipe, a glass process seal or the wall of a wooden chute to detect the material inside the encasement. It includes a switchable filter which reduces the effect of vibration and ensures the detection of moderate and fast-flowing materials. A single analog relay output communicates flow or no flow status to a PLC and has the option of using both normally open (NO) and normally closed (NC) contacts. LED indicator lights inform the end user of the device's status.


Features:
• Contains the sensing element, power and output connections, and user adjustment controls in a single NEMA 4X enclosure
• Can pass through non-metallic materials
• Easy Installation
• Uses Doppler technology (microwave) to provide reliable motion detection
• Non-intrusive flush mounting senses through non-metallic surfaces
• Non-contact operation eliminates flow stream interruption and equipment wear
• LED lights for flow/no flow status


Applications:
• Used for solids, granules, pellets, meals and powdered materials
• Suitable for most industries, including feed, grain, milling, food, cement, mining, power and plastics






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

Flow Detect 2000
(PDF, 1178KB)

Level Indicator Product Selection Chart
(PDF, 1138KB)

BinMaster Full Line Brochure
(PDF, 2494KB)

   
  Results 1 - 1 of 1 1 

Item #

Power Requirements

Detection Range

Sensitivity Adjustment

Relay Outputs

Output Delay Range

Fault Conditions

Operating Temperature

Emissions

Enclosure

Mounting

Conduit Entry

Process Pressure

730-0668 1 Watt at 24 VDC +/-10% 1.5 m (4.9 ft.) High / low selection switch with potentiometer 250 VAC / 220 VDC / 2A (N.C. or N.O.) Switchable from 0.1 to 3.1 seconds / 2.3 to 15.1 seconds Doppler sensor failure and excessive temperature -10°C to 55°C (14°F to 131°F) 24.11 GHz, 6.6 mW typical / 9.9 mW maximum White Powder Coated Aluminum, NEMA 4X 1-1/4” NPT 3/4” NPT 80 PSI