Features:
• Soft starting and smooth ramp-down
• Stepless starting
• Reduction of current peaks
• Reduced load on the power supply network
• Reduction of the mechanical load in the operating mechanism
• Avoidance of mains voltage fluctuations during starting
• Considerable space savings and reduced wiring compared with conventional starters
• Maintenance-free switching

Performance range:
• Up to 900 HP (at 460 volt) inline circuit
• Up to 1600 HP (at 460 volt) inside-delta circuit

In addition to soft starting and soft ramp-down, the solid state 3RW44 softstarters provide numerous function for higher-lever requirements. The new torque control and adjustable current limiting enable the high-feature soft starters to be used in nearly every application. They guarantee the reliable avoidance of sudden torque applications and current peaks during motor starting and stopping. This creates savings potential when calculating the size of the switchgear and when servicing the machinery installed.

The bypass contacts already integrated in the softstarter bypass the thermistors after a motor ramp-up is detected. This results in a further reduction in the heat loss occurring during operation of the softstarter.

Combinations of various starting operating and ramp-down possibilities ensure an optimum adaptation to the application specific requirements.

 






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

General Purpose Enclosed Drive Package
(PDF, 540KB)

Electric Motor Controls
(PDF, 9231KB)

Compare Items
   
  Results 76 - 88 of 88 1 2 3 4 

Item #

HP at 200 Volts

HP at 230 Volts

HP at 460 Volts

Rated Operational Current

Terminal Type

Supply Voltage

3RW4457-6BC44 250 300 600 780 Screw 230
3RW4458-2BC34 300 250 700 850 Spring 115
3RW4458-6BC34 300 250 700 850 Screw 115
3RW4458-2BC44 300 250 700 850 Spring 230
3RW4458-6BC44 300 250 700 850 Screw 230
3RW4465-2BC34 350 400 800 970 Spring 115
3RW4465-6BC34 350 400 800 970 Screw 115
3RW4465-2BC44 350 400 800 970 Spring 230
3RW4465-6BC44 350 400 800 970 Screw 230
3RW4466-2BC34 350 400 900 1076 Spring 115
3RW4466-6BC34 350 400 900 1076 Screw 115
3RW4466-2BC44 350 400 900 1076 Spring 230
3RW4466-6BC44 350 400 90 1076 Screw 230