Search Catalog
      GO   
 All Products    SCP1000 / SCP2000 Shaft Speed Switch
All Products > Machine and Hazard Monitoring > Speed Switches > SCP1000 / SCP2000 Shaft Speed Switch > View Items  

SCP1000 / SCP2000 Shaft Speed Switch

Check up to five results to perform an action.

 

Features:
• Single or double relay setpoint(s)
• Failsafe operation 
• Built-in start delay
• Selectable under-speed or over-speed 
• Setpoint ranges: 1-100 and 10-1,000 rpm
• Visual setpoint adjustment with digital accuracy
• Class I, Div I (C, D) Class II, Div I (E, F, G)

 

SCP Series Switches are ideal for applications where speed indication for alarm and shutdown purposes is critical for safe and efficient equipment operation. The SCP1000 (single relay) and SCP2000 (single or double relay) feature rotary dials for precise setpoint adjustment and can be completely calibrated with the machinery at rest. Digital circuitry provides high accuracy, repeatability, and reliability. They are the industry standard for protecting bucket elevators, fans, airlocks, mixers, or virtually any rotating shaft, including overspeed sensing requirements.

 

PTU-1000 Test Unit
The PTU Test Unit can be used with the SCP Speed Switch to verify shaft speed or to simulate any unwanted condition for test purposes. Each SCP1000 and SCP2000 is equipped with a portable test jack for use with the PTU-1000.


Optional Mounting Magnet: MM-2.00

• No Drilling or Tapping Required!
• For use with the EZ-SCP Mounting Bracket only






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

SCP1000 \ SCP2000 Data Sheet
(PDF, 3138KB)

Shaft Speed Switch Selection Guide
(PDF, 1448KB)

Machine and Hazard Monitoring Systems
(PDF, 2047KB)

Compare Items
   
  Results 1 - 8 of 8 1 

Item #

Input Power

Operating Temperature

Number of Setpoints

Setpoint Range

Enclosure Mount

Housing Material

Certifications

800-020100 115 VAC -40°F to +140°F 1 1-99 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-021100 230 VAC -40°F to +140°F 1 1-99 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-023100 12 VDC -40°F to +140°F 1 1-99 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-022100 24 VDC -40°F to +140°F 1 1-99 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-040100 115 VAC -40°F to +140°F 2 10-999 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-041100 230 VAC -40°F to +140°F 2 10-999 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-043100 12 VDC -40°F to +140°F 2 10-999 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
800-042100 24 VDC -40°F to +140°F 2 10-999 RPM 1-Inch NPT Conduit Opening Cast Aluminum ISO 9001
  Results 1 - 8 of 8 1