Search Catalog
      GO   
 All Products    Explosion Proof Motors C-Face
All Products > Conveyors and Conveyor Products > Conveyor Components > Electric Motors, Motor Controls and Gear Reducers > Electric Motors > Explosion Proof Motors C-Face > View Items  

Explosion Proof Motors C-Face

Check up to five results to perform an action.


WorldWide Electric’s line of Explosion Proof motors are designed and built to meet both Class I and Class II requirements. These motors are fully tested in order to obtain an explosion proof rating.

*Currently being redesigned to include inverter duty to withstand the higher voltage produced by VFDs.

Features:
• 2-300 HP
• 1800 RPM
• 208-230/460 volt (2-100 HP)
• 460 volt (125-300 HP)
• TEXP enclosure
• 1.15 service factor
• Class F insulation
• C-face - rigid base
• Premium efficiency (2-200 HP)
• High efficiency (250-300 HP)
• Inverter duty, 5:1 CT / 10:1 VT (1-200 HP only)
• Three normally closed winding thermostats provided (one per phase)
• UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
• 145TC-215TC: Class 1, Div. 1, Groups C & D; T3C; inverter duty (1-200 HP); 55ºC amb. temp.
• 254TC-449TC: Class 1, Div. 1, Groups C & D; T2C; inverter duty (1-200 HP); 55ºC amb. temp.
• Three-Phase






    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 DOWNLOADS 

Electric Motors Catalog (2017-2018)
(PDF, 11611KB)

Compare Items
   
  Results 1 - 19 of 19 1 

Item #

HP

RPM

Voltage

Frame

Enclosure

FL Amps (A)

FL Eff. (%)

Approx. Weight (lbs.)

Certifications

IXPEWWE2-18-145TC 2 1800 208-230/460 145TC TEXP 2.8 86.5 73 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
IXPEWWE3-18-182TC 3 1800 208-230/460 145TC TEXP 3.8 89.5 121 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
IXPEWWE5-18-184TC 5 1800 208-230/460 184T TEXP 6.2 89.5 131 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
IXPEWWE7.5-18-213TC 7.5 1800 208-230/460 213TC TEXP 9.2 91.7 237 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
IXPEWWE10-18-215TC 10 1800 208-230/460 215TC TEXP 12.4 91.7 243 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
IXPEWWE15-18-254TC 15 1800 208-230/460 215TC TEXP 16.9 92.4 393 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE20-18-256TC 20 1800 208-230/460 256TC TEXP 23 93 435 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE25-18-284TC 25 1800 208-230/460 284TC TEXP 27.9 93.6 516 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE30-18-286TC 30 1800 208-230/460 286TC TEXP 33 93.6 523 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE40-18-324TC 40 1800 208-230/460 324TC TEXP 45.5 94.1 670 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE50-18-326TC 50 1800 208-230/460 326TC TEXP 57 94.5 715 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE60-18-364TC 60 1800 208-230/460 364TC TEXP 68.5 95 920 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE75-18-365TC 75 1800 208-230/460 365TC TEXP 83.5 95.4 985 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE100-18-405TC 100 1800 208-230/460 405TC TEXP 113 95.4 1350 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE125-18-444/5TC 125 1800 460 444/5TC TEXP 134 95.4 1555 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE150-18-444/5TC 150 1800 460 444/5TC TEXP 163 95.8 1740 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XPEWWE200-18-445/7/9TC 200 1800 460 444/5TC TEXP 223 96.2 1990 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XWWE250-18-447/9TC 250 1800 460 447/9TC TEXP 275 95.2 2560 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
XWWE300-18-447/9TC 300 1800 460 447/9TC TEXP 325 95.4 2745 UL Listed Class 1, Div. 1, Groups C & D; Class 2, Div. 1, Groups F & G; T3C; inverter duty (1-200 HP), 40º amb. temp. as standard
  Results 1 - 19 of 19 1